How many lux do you need: reference levels for homes (EN 12464-1 orientation)
Watts are about electricity, lumens are about the lamp, and lux is about how much light actually lands on the table, floor and walls. European standard EN 12464-1 sets minimum illuminance for each room type. Here's what it says, how to read our widget's report, and where the limits of this estimate are.
1. Quick vocabulary
- Lumen (lm) — how much light the source emits in total. An LED gives roughly 80–110 lm per watt.
- Lux (lx) — how much light lands on a unit area: 1 lx = 1 lm/m². Standards are written in lux.
- CCT — correlated color temperature (Kelvins), affects mood and paint color rendering.
- Ra/CRI — color rendering index, how honestly the lamp shows colors.
- UGR — glare index, how much the fixture “blinds”.
2. Reference levels for residential spaces (EN 12464-1 orientation, appendix Л of СП 52.13330.2016 matches)
| Space | Illuminance on task surfaces | Comment |
| Storage, utility | 30–50 lx | Navigation only, no task work |
| Corridors, hallways, bathrooms | 50 lx | Measured on the floor |
| Living rooms, kitchens | 150 lx | On the floor / on the countertop |
| Nurseries / kids' rooms | 200 lx | Higher demand for children's eyes |
| Studies, libraries | 300 lx | On the task plane (desk) |
| Offices (for comparison) | 300–500 lx | Defined in the lighting project |
The widget's standards bars follow exactly this table — the white mark on each bar is the required lux level.
3. How the widget computes illuminance
The widget makes an estimate two ways:
Direct point: E = I × cos α / d², where I = Φ/Ω — luminous intensity (cd), d — distance, α — angle of incidence
Room average (lumen method): E ≈ Φ / (A × (1 − ρavg))
- Key point — the center of the spot on the wall (or the floor under the lamp in “overhead” mode): the direct component of the beam.
- Floor — average: the lumen method using your paint's LRV and the floor.
- Luminous flux is taken as ~100 lm/W for LEDs — adjust for your lamp (incandescent ~12, halogen ~18, fluorescent ~65 lm/W).
4. Where this estimate ends
Honestly, what the widget (and any online tool without a scene calculation) doesn't account for:
- Furniture and people absorb and shade light;
- Glare (UGR) and flicker aren't evaluated;
- Real lamps have a luminous intensity distribution — by angles, not an ideal cone;
- Standards are evaluated on the task plane (floor — 0 m, desk — 0.8 m), while the widget shows scene points.
So the report is a comparison tool and reference point: it answers “is 40 W enough for 150 lx in this room with this paint” and “how much darker will it get in graphite” perfectly well. For a working project — a lighting engineer's calculation (DIALux/Relux to EN 12464-1).
5. Color temperature and comfort
The standard sets “how much”, CCT sets “how”. Per the Kruithof curve: warm light (2700–3000 K) is comfortable around 50–400 lx; cool light (5000–6500 K) starts feeling right only at high illuminance (from 300–500 lx). That's why for a bedroom with evening light you shouldn't buy 6500 K “to make it brighter” — at 150 lx it will look grim and bluish. The widget shows this range under the standards bars.
6. Checklist: fit the standards to your room
- Pick your paint in the widget (LRV fills in automatically).
- Set your lamp's power in watts (or convert: lm/100 = LED “watts”).
- Choose the “Overhead” direction — the closest scenario to a ceiling fixture.
- Watch the bars: the goal is to land past the white mark for your room type.
- If short — add power/fixture count or pick a lighter paint.
Sources
- EN 12464-1 “Light and lighting — Lighting of work places — Part 1: Indoor work places” — the European reference standard.
- СП 52.13330.2016 “Natural and artificial lighting” (updated СНиП 23-05-95), appendix Л — the Russian norm (matches the table above).
- CIE S 008/E “Lighting of Indoor Work Places” — the international basis of the norms.
- Kruithof, A. A. (1941) — the comfort dependency of CCT × illuminance pairs.