Light Reflectance Value (LRV): how much light walls give back

The same lamp “works” almost twice as bright in a white room as in a dark-blue one. The reason is the paint's reflectance. Let's break down what LRV is, how RAL relates to it, and how wall lightness affects illuminance and your power bill.

1. What LRV is

LRV (Light Reflectance Value) — the fraction of visible light a surface reflects. Measured in percent from 0 (perfect black) to 100 (perfect white). It's not “color brightness” but strictly physical lightness: two colors of equal lightness, say grey and dusty blue, will have a similar LRV.

Every RAL has its own LRV: white RAL 9016 is about 87%, mid-grey RAL 7042 about 27%, black-blue RAL 5004 about 4%. That's exactly why the widget's “Reflectance” slider auto-fills when you pick a paint.

2. Why it matters: light travels in circles

The lamp shines once, but in a room light reflects repeatedly: wall → floor → wall. Every hit loses a share (1 − ρ). Total illuminance is the direct component plus a geometric progression of the reflected ones:

Eavg ≈ Φ / ( A × (1 − ρavg) )

where Φ — lamp luminous flux (lm), A — total reflective area (walls + floor, m²), ρavg — weighted average reflectance.

Example. Room 5×5 m, height 2.7 m. Walls 54 m² + floor 25 m² = 79 m². Lamp 5000 lm.
• Walls RAL 9016 (ρ≈0.87), floor 0.35 → ρavg ≈ 0.73 → E ≈ 5000/(79×0.27) ≈ 235 lx
• Walls RAL 5010 (ρ≈0.07), floor 0.35 → ρavg ≈ 0.15 → E ≈ 5000/(79×0.85) ≈ 75 lx
A 3× difference — with the very same lamp.

3. Dark walls aren't “moody” — they're “need more lumens”

The graphite-wall trend is beautiful, but it has a price: to get the same 150 lx in a living room with ρ≈0.15 you need three times the luminous flux. In practice:

4. LRV and perceived color under light

There's a reverse effect too: light paint under bright light looks even lighter and more saturated (the Hunt effect: perceived colorfulness grows with brightness). So a pastel RAL 1015 in a dim room at 2200 K looks “dusty”, while at 300 lx 4000 K it looks noticeably “yellower and livelier”. The widget reproduces this: move the power slider at a fixed temperature and watch the color comparison.

5. Practical recommendations

  1. Count the lighting budget before painting. Total flux (lm) = target (lx) × floor area / (0.5…0.6) — a rough loss correction. The widget report does this estimate for you using the selected paint's LRV.
  2. Dark accent walls — plan dedicated directional light for them: an absorbing color demands its “own” portion of lumens.
  3. Gloss doesn't add light, it redistributes: mirror reflection creates bright highlights and dark voids. For evenness prefer a matte paint with a light LRV.
  4. Mixed rooms: if one wall is dark and the rest are light, the weighted ρ drops only slightly and the room barely loses illuminance. Calculate over all surfaces, not one wall.

6. How it works in the widget

The illuminance report uses your actual paint: the “Reflectance” slider takes LRV from the RAL database (you can adjust it manually — e.g. for other manufacturers). The report shows the direct illuminance at the key point (wall/floor) and the room-average estimate, oriented to EN 12464-1 levels.

Sources
  1. ГОСТ Р 59501-2021 / RAL Design System — lightness and reflectance values for RAL atlases.
  2. EN 15193 / ASHRAE 90.1 — surface reflectance as an input to lighting energy calculations.
  3. CIE 29.2 “CIE Guide on Interior Lighting” — lumen method for average illuminance.
  4. Hunt, R. W. G. (1965) — the Hunt effect (perceived saturation grows with brightness).
  5. WELL Building Standard, “Surface Design” feature — reflectance benchmarks for healthy buildings.